一. 在線分析總有機碳分析儀 工作原理 Working principle
本儀器采用紫外氧化的原理,將樣品中的有機物氧化為二氧化碳,二氧化碳的測試采用的是直接電導率法,通過測試經(jīng)過氧化反應的樣品的總碳含量和未經(jīng)過氧化反應的樣品總無機碳的含量差值來測定總有機碳含量,即:總有機碳(TOC)=總碳(TC)-總無機碳(TIC)。
The instrument adopts the principle of UV oxidation, the oxidation of organic matter in the sample for carbon dioxide, carbon dioxide is tested by direct conductivity method, the total carbon content through the test after oxidation samples and samples without content difference of total inorganic carbon oxidation reaction to the determination of total organic carbon content, namely: Total Organic C (TOC) = total carbon (TC) and total inorganic carbon (TIC).
二. 在線分析總有機碳分析儀 產(chǎn)品特點 Product features
1.儀器采用便攜設計,使用輕便,方便移動至取樣點。
1. portable design, easy to use, easy to move to the sampling point.
2.采用嵌入式系統(tǒng),觸摸屏設計,純中文操作方便簡易。
2., using embedded system, touch screen design, pure Chinese, easy to operate.
3.針對制藥用水(TOC含量在1000ppb以下)總有機碳含量的檢測設計,進行檢測。
3. for the pharmaceutical water (TOC content below 1000ppb) total organic carbon content of the detection design, testing.
4.配備大量的儲存空間,能夠存儲大量的測試數(shù)據(jù)。
4. is equipped with a large amount of storage space, can store a large number of test data.
5.中文打印,輸出測試參數(shù)、測試結(jié)果。
5. print in Chinese, output test parameters and test result.
6.在使用、貯存和更換過程中不需要氣體或試劑,無移動部件,減少維修和維護成本。
6. in use, storage and replacement process, there is no need for gas or reagents, no moving parts, and less maintenance and maintenance costs.
7.當測試樣品濃度超過規(guī)定限度,儀器能夠自動報警,并輸出控制信號。
7. when the concentration of the test sample exceeds the specified limit, the instrument can alarm automatically and output control signals.
8.符合國家2010版《中國藥典》規(guī)定的測試方案,可以提供 IQ/OQ/PQ 服務。
8., in line with the national 2010 edition of the "Chinese Pharmacopoeia" provisions of the test program, you can provide IQ/OQ/PQ services.
三、 在線分析總有機碳分析儀 技術參數(shù)及特點 Technical parameters and characteristics
3.1 主要技術參數(shù) Main technical parameters
電 源 Power supply:220V±22V
電源頻率 Power frequency:50Hz±1Hz
額定功率 Rated power:100W
基本尺寸 Basic size:44cm×18cm×26cm
檢測極限 Detection limit:0.001mg/L
檢測精度 Detection accuracy:±5%
檢測范圍 Detection range:0.001mg/L~1.000mg/L
分析時間 Analysis time:4min
響應時間 Response time:15 min以內(nèi)
樣品溫度 Sample temperature:1-95℃
環(huán)境溫度 Ambient temperature:10-40℃ 溫度變化在±5℃/d以內(nèi)
內(nèi)部樣品流速 Internal sample flow rate:0.5 ml/min
相對濕度 Relative humidity:≤ 85%
重復性誤差 Repeatability error:≤ 3%
零點漂移 Zero drift:±5%
量程漂移 Range drift:±5%
3.2 在線分析總有機碳分析儀 特點 ?Characteristic
① 不需要添加酸試劑、氧化劑和任何氣體,無需附加日常維護費。
② 操作簡單、快捷、可靠。使用者無需專業(yè)知識和專門培訓。
③ 針對TOC1000ppb以下去離子水的檢測設計,在線、離線檢測可以切換使用。
④ 超大的存儲器能自動存儲zui近12個月連續(xù)檢測的數(shù)據(jù),可以查詢?nèi)我庖惶斓?/span>檢測記錄,并能打印檢測結(jié)果。
⑤ 檢測速度快,一次檢測分析時間僅為4分鐘。
⑥ 同步檢測水樣的電導率值,將TOC分析儀與電導率儀合二為一。
⑦ 體積小、重量輕、耗能少、攜帶方便。
⑧ 具有自動的上限報警輸出,超出設定的檢測結(jié)果時可以提醒操作者。
⑨ 易于按照USP <643>和EP <2.2.44>以及中國藥典2005年版附錄Ⅷ R所要求的TOC檢測方法進行系統(tǒng)適應性驗證。
⑩ 超大的320´234的點陣真彩顯示器以及人性化的界面,具有RS232數(shù)據(jù)接口和打印機接口。
There is no need to add acid reagents, oxidants and any gas without additional maintenance costs.
The operation is simple, quick and reliable. Users do not need professional knowledge and specialized training.
For the detection and design of deionized water under TOC1000ppb, on-line and off-line detection can be switched.
Super memory can automatically store the last 12 months of continuous detection of data, you can query any day of the test records, and print the results of the test.
The detection speed is fast, and the analysis time is only 4 minutes at one time.
The simultaneous detection of water conductivity value, TOC analyzer and conductivity meter will be made one.
The small volume, light weight, low energy consumption, easy to carry.
It has automatic limit alarm output, so that the operator can set the test results beyond.
Easy to TOC method in accordance with the requirements of USP <643> and EP <2.2.44> and China Pharmacopoeia 2005 edition appendix VIII of R system to verify.
The large 320 234 dot matrix color display, user-friendly interface, data interface and printer interface with RS232.
四、 在線分析總有機碳分析儀 儀器各部件的安裝、連接
開箱后,按以下步驟進行安裝:
── 根據(jù)裝箱單檢查儀器是否齊備。
── 確定儀器在運輸過程中沒有遭到損壞。
── 拆除機箱的外包裝,將其置于正確位置 。
── 檢查儀器保險絲是否裝好,連接市電電纜到接線端子。
── 根據(jù)安裝圖連接進液和出液管路 。
── 系統(tǒng)通電 。
Installation and connection of all parts of the instrument
After unpacking, install as follows:
Check the equipment according to the packing list.
- make sure the instrument is not damaged during transit.
- remove the outer packing of the case and place it in the correct position.
Check that the instrument fuse is fixed and connect the mains cable to the terminal.
Connect the inlet and outlet lines according to the installation drawing.
System electrify.
五、安裝
1 安裝位置的選擇
將儀器放在一個潔凈、無障礙物的平面上,并保證除儀器外還能承載 25kg的重量,為了便于散熱,請確保儀器的后面和兩側(cè)留有至少16cm的空間。
2 電源要求
電壓:220V ± 22V
電源頻率:50Hz ± 1Hz
3 環(huán)境要求
儀器應在一個恒溫恒濕且適于工作的環(huán)境中進行。避免陽光直射和超常溫度;溫度過高(超過104°F,40℃)會導致運行失常,溫度過低(低于50°F,10℃)會導致測量值誤差過大。
install
1 Selection of installation location
Place the instrument on a clean, barrier free surface and guarantee the weight of the 25kg in addition to the instrument. Be sure to leave at least 16cm of space in the back and sides of the instrument for ease of heat dissipation.
2 power requirements
Voltage: 220V + 22V
Power frequency: 50Hz + 1Hz
3 environmental requirements
The instrument should be in a constant temperature and humidity environment suitable for work. Avoid direct sunlight and excessive temperature; the temperature is too high (over 104 degrees F, 40 degrees Celsius) will lead to abnormal operation, the temperature is too low (lower than 50 degrees F, 10 degrees Celsius) will lead to too much error in measurement.
歡迎您選用我公司開發(fā)研制的各類檢測儀器。在使用過程中,如出現(xiàn)什么問題,可隨時和我們,您將得到良好的售后服務。真誠的希望您能將寶貴的意見,豐富的經(jīng)驗和獨到的見解反饋給我們!
:
You are welcome to choose all kinds of testing instruments developed by our company. In the process of use, if any problems, you can contact us at any time, you will get good after-sales service. We sincerely hope that you will give us your valuable advice, experience and insights!
Contact number: :